Modelling the AFM tip effect for quantitative analysis of precipitate volume fraction in nickel-based superalloys

Michel Troyon1, Alain Hazotte2 et Abderrahim Bourhettar1

1  Laboratoire de Microscopie Electronique, GRSM, Université de Reims, 21 rue Clément Ader, 51100 Reims, France
2  Laboratoire de Science et Génie des Matériaux Métalliques, Ecole des Mines de Nancy, Parc de Saurupt, 54041 Nancy Cedex, France


Abstract
A method to measure the precipitate volume fraction in nickel-based superalloys by using atomic force microscopy is described. Taking into account the geometry of the AFM tip and modelling the depth-level histogram of the image permits a good understanding of the role played by the different experimental parameters, and allows a good estimate of the γ' precipitate volume fraction to be obtained.


Résumé
Une méthode pour mesurer la fraction volumique des précipités dans les superalliages à base de Nickel par microscopie à force atomique est décrite. La prise en compte de la géométrie de la pointe et le développement d'un modèle théorique de l'histogramme des niveaux de profondeur dans l'image permettent de bien comprendre quel rôle les différents paramètres expérimentaux jouent et comment obtenir une bonne estimation de la fraction volumique des précipités γ'.

PACS
0779L - Atomic force microscopes.
6837P - Atomic force microscopy (AFM).
8105B - Metals, semimetals, and alloys.

Key words
Precipitation -- Volume fraction -- Superalloys -- Atomic force microscopy -- Modeling -- Precipitates -- Microstructure -- Nickel base alloys -- Prime gamma phase -- Materials science -- Physics -- Metals -- Metallurgy